This is the latest recevied telemetry packets stored in our database for station/object SR2LMU-2. If no packets are shown the sender has not sent any telemetry packets the latest 10 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
Time | TX* | RX* | Digi* | V_Bat* | V_Ext* |
---|---|---|---|---|---|
1743749307 | 0 Count | 913 Count | 0 Count | 4.21 VDC | 0 VDC |
1743745707 | 0 Count | 904 Count | 0 Count | 4.21 VDC | 0 VDC |
1743742107 | 0 Count | 893 Count | 0 Count | 4.2 VDC | 0 VDC |
1743738507 | 0 Count | 884 Count | 0 Count | 4.2 VDC | 0 VDC |
1743734907 | 0 Count | 875 Count | 0 Count | 4.21 VDC | 0 VDC |
1743731307 | 0 Count | 866 Count | 0 Count | 4.2 VDC | 0 VDC |
1743727707 | 0 Count | 857 Count | 0 Count | 4.22 VDC | 0 VDC |
1743724107 | 0 Count | 848 Count | 0 Count | 4.22 VDC | 0 VDC |
1743720506 | 0 Count | 839 Count | 0 Count | 4.21 VDC | 0 VDC |
1743716906 | 0 Count | 831 Count | 0 Count | 4.21 VDC | 0 VDC |
1743713306 | 0 Count | 823 Count | 0 Count | 4.21 VDC | 0 VDC |
1743709706 | 0 Count | 814 Count | 0 Count | 4.21 VDC | 0 VDC |
1743706106 | 0 Count | 799 Count | 0 Count | 4.21 VDC | 0 VDC |
1743702506 | 0 Count | 791 Count | 0 Count | 4.21 VDC | 0 VDC |
1743698906 | 0 Count | 781 Count | 0 Count | 4.21 VDC | 0 VDC |
1743695306 | 0 Count | 773 Count | 0 Count | 4.2 VDC | 0 VDC |
1743691706 | 0 Count | 764 Count | 0 Count | 4.2 VDC | 0 VDC |
1743688108 | 0 Count | 755 Count | 0 Count | 4.21 VDC | 0 VDC |
1743684508 | 0 Count | 746 Count | 0 Count | 4.2 VDC | 0 VDC |
1743680908 | 0 Count | 738 Count | 0 Count | 4.19 VDC | 0 VDC |
1743677308 | 0 Count | 730 Count | 0 Count | 4.2 VDC | 0 VDC |
1743673708 | 0 Count | 722 Count | 0 Count | 4.22 VDC | 0 VDC |
1743670108 | 0 Count | 714 Count | 0 Count | 4.22 VDC | 0 VDC |
1743666507 | 0 Count | 701 Count | 0 Count | 4.21 VDC | 0 VDC |
1743662907 | 0 Count | 686 Count | 0 Count | 4.2 VDC | 0 VDC |
*Used Equation Coefficients:
TX: 0, 1, 0
RX: 0, 1, 0
Digi: 0, 1, 0
V_Bat: 0, 0.01, 0
V_Ext: 0, 0.02, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)