This is the latest recevied telemetry packets stored in our database for station/object SR2LMU-10. If no packets are shown the sender has not sent any telemetry packets the latest 10 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
Time | TX* | RX* | Digi* | V_Bat* | V_Ext* |
---|---|---|---|---|---|
1743751394 | 29 Count | 246 Count | 15 Count | 4.08 VDC | 5.38 VDC |
1743750501 | 27 Count | 218 Count | 14 Count | 4.08 VDC | 5.38 VDC |
1743748694 | 19 Count | 173 Count | 12 Count | 4.07 VDC | 5.38 VDC |
1743747795 | 16 Count | 154 Count | 10 Count | 4.08 VDC | 5.36 VDC |
1743746893 | 14 Count | 134 Count | 9 Count | 4.08 VDC | 5.36 VDC |
1743745994 | 11 Count | 114 Count | 7 Count | 4.07 VDC | 5.36 VDC |
1743745094 | 9 Count | 86 Count | 6 Count | 4.07 VDC | 5.36 VDC |
1743744195 | 6 Count | 65 Count | 4 Count | 4.06 VDC | 4.22 VDC |
1743743294 | 3 Count | 41 Count | 2 Count | 4.04 VDC | 4.2 VDC |
1743742394 | 1 Count | 22 Count | 1 Count | 4 VDC | 4.18 VDC |
1743741493 | 158 Count | 1017 Count | 84 Count | 3.99 VDC | 4.16 VDC |
1743740595 | 154 Count | 993 Count | 81 Count | 3.97 VDC | 4.14 VDC |
1743739694 | 153 Count | 978 Count | 81 Count | 3.96 VDC | 2.58 VDC |
1743738795 | 150 Count | 951 Count | 79 Count | 3.96 VDC | 0.02 VDC |
1743737895 | 149 Count | 936 Count | 79 Count | 3.96 VDC | 0 VDC |
1743736995 | 146 Count | 912 Count | 77 Count | 3.96 VDC | 0 VDC |
1743736095 | 144 Count | 897 Count | 76 Count | 3.96 VDC | 0 VDC |
1743735196 | 141 Count | 870 Count | 74 Count | 3.96 VDC | 0 VDC |
1743734296 | 139 Count | 846 Count | 73 Count | 3.96 VDC | 0 VDC |
1743733396 | 137 Count | 827 Count | 72 Count | 3.96 VDC | 0 VDC |
1743732497 | 135 Count | 805 Count | 71 Count | 3.96 VDC | 0 VDC |
1743731597 | 132 Count | 783 Count | 69 Count | 3.96 VDC | 0 VDC |
1743730697 | 131 Count | 766 Count | 69 Count | 3.96 VDC | 0 VDC |
1743729797 | 128 Count | 740 Count | 67 Count | 3.96 VDC | 0 VDC |
1743728897 | 126 Count | 720 Count | 66 Count | 3.97 VDC | 0 VDC |
*Used Equation Coefficients:
TX: 0, 1, 0
RX: 0, 1, 0
Digi: 0, 1, 0
V_Bat: 0, 0.01, 0
V_Ext: 0, 0.02, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)